Server rooms & data centers – HelvetiaSafe

Server rooms & data centers

Clean Aerosol protection inside racks and in the room, combined with ABC product and ABC fire balls for full coverage – without water damage.

Electronics-friendly
Electronics-friendly

Aerosol does not flood the room with water and is much gentler on sensitive electronics than classic sprinklers or many liquid agents.

Fast localized activation
Fast localized activation

Modules activate directly in the affected rack or room zone, stopping the fire at an early stage.

Flexible system design
Flexible system design

Aerosol units inside each cabinet plus room modules, with ABC product and ABC fire balls in the corners of the room.

Typical applications

HelvetiaSafe solutions are ideal wherever IT infrastructure must stay online – without water damage or long downtimes.

Server racks & cabinets Core switch rooms Data centers UPS & battery rooms Network distribution rooms Control rooms

How the concept works

  • Aerosol units are mounted inside each cabinet and in defined positions within the server room.
  • When the trigger temperature is reached, Aerosol is released into the protected volume and interrupts the combustion process.
  • ABC product and ABC fire balls can be placed in room corners and specific hotspots to protect open areas.
  • The result is clean suppression with no sprinkler water flowing over racks, servers and cables.

Configuration

  • Racks protected individually with Aerosol units sized to the internal cabinet volume.
  • Room modules dimensioned according to the total room volume and risk profile.
  • ABC product and fire balls positioned in corners and along cable routes or hotspots.
  • System concept designed project-specifically by HelvetiaSafe, according to applicable standards and local regulations.
Request server room concept Send us a simple sketch or description of your server room – racks, room size and special risks – and we prepare a proposal for Aerosol, ABC product and fire balls.
Can Aerosol replace sprinklers in the server room?

In many projects Aerosol systems are used as an alternative to classic water sprinklers in server rooms, because they do not soak racks and electronics. When designed correctly and in line with local regulations, Aerosol units inside cabinets and additional room modules can provide the main fire-protection concept.

Do Aerosol units damage servers or data?

Aerosol avoids water damage and is engineered to minimise impact on electronics compared with sprinkler discharge or many conventional extinguishers. Cleaning is significantly easier than after a water event.

Why add ABC product and ABC fire balls?

Aerosol protects the inside of cabinets and defined room volumes. ABC product and ABC fire balls cover corners, cable routes or underfloor voids where a handheld extinguisher would be hard to use quickly.

Can the system be retrofitted in an existing server room?

Yes. Racks can be equipped step-by-step with Aerosol modules, and room units, ABC product and fire balls can be added during planned maintenance windows.